Robamat
Visit us :- www.robamat.com

Thermal Technology - Oil

max°C kw kw/150k Ltr/min.bar L/B/H/ mm kg
250 7/10 20
60.6 850/330/800/940 120
250 10/20 20/40/60
60.6 1050/385/870/1020 160
320 10/20 20/40/60
60.6 1050/350/870/1020 160
350(250) 10/20 20/40/60 75.11 1050/385/870/1020 180
350(250) 30/40 20/40/60 75.11 1050/500/1125/1300 220
250 2X10/20 2X20/40/60 2X60.6 1050/500/1125/1300 270
320 2X10/20 2X20/40/60 2X60.6 1050/500/1125/1300 270
350(250) 2X17/20 2X20/40/60
2X75.11 1050/500/1125/1300 300
350(250) 2X30/40 2X20/40/60 2X75.11 1050/695/1125/1300 380

Structure :- Solid housing framework, integrated switch cabinet. Easy accessibility through removable doors and covers. Optimal heat exchange thanks to approved pressurized heating and cooling system.

Register :- Heating and cooling system designed in the form of a pipe register system. High degree of flexibility in the installation of heaters and coolers. Special ceramic fiber for optimal thermal insulation.

Heater :- Casted in aluminium. Integrated channels for heat transfer fluid. Heater temperature monitoring.

Cooler :- Stainless steel pipe casted in aluminium. Channeled pressurized cooling water.

Feed Technology :- Magnetic coupled periferial pumps for leak-free operation. Feed pump with reservoir, automatic ventilation, cold oil overlap, oil return suction, leak-stop operation

Process Control
  • Important :- Permanent process control.
  • Simple :- Operator panel with big keys.
  • Easy to read :- Digital display of setpoint/actual temperature.
  • Advantageous :- Self-optimizing microprocessor.
  • Practical :- Start - Production - End - Stop - mode.
  • Clear :- Status and error indication.
  • Reliable :- Interrogation possibility of internal
    machine conditions.
  • Control :- Monitoring of pump motor.
  • Automatic :- Switching of heating and cooling stage.
  • Individual :- Supervision of heater temperature
    and heat transfer fluid level/pressure.
  • Optimal :- Safety shutoff in case of overtemperature.
  • Integrated :- Operating hours meter. weekday time switch, alarm system.

Accessories :- Pressure measurement, flow rate indication, pause time switch. RS485 interface, external sensor, blow out device for cooling water, automatic oil return suction, central fault indication.

Units made to specification :-
On your demand

System structure
  • Pressurized convection heater
  • Pressurized convection cooler
  • Feed pump with reservoir
  • Expansion tank and fluid reservoir
  • Supervision of heat transfer fluid level
  • Solenoid valve for cooling water
  • Bypass
  • Temperature sensor - heat transfer fluid
  • Temperature sensor - heater

Products

Heating .Cooling.Temperature control .Robamat units get the job done.from the intial sketches to professional completion. Our products go through a well-conceived cycle. Single circuit units.Double circuit units- a synthesis of technology and high standards: From Know-how and a wealth of experience.

Rugged. Professional, Practical. Robust housing framework, integrated switch cabinet. Heating and cooling systems for optimum heat exchange. Comprehensive, well-thought-out units.

Simple. Precise. Modular. Beauty outside. Quality inside. Flexibility in a small space. Ongoing development of a powerful concept.

  • Hi-Tech. High Spirits, High Quality.
  • You simply connect the Robamat temperature control unit.
  • It does the rest. No ifs. No buts.
  • Robamat temperature control units.
  • With 20 years of experience. Thousands of endurance tests.
  • Countless quality controls. Day in day out.
  • The toughest practical service in the die casting industry.
  • The best solution for you.